Petra Mechatronics Middle East | Authorized reseller of SiGMA
A/D conversion method: Sigma-delta conversion method
Input signal range: -3mV~15mV
Sensor bridge power supply: DC 5V
Number of connected sensors: Up to four 350Ω sensors can be connected
Sensor Connection: 4-wire system
Verification division: 2000~3000
The maximum degree of external division: 15000
Division value: 1/2/5/10/20/50 optional
Display method: LCD segment display, multi-state flag bit indication
Wireless transmission frequency: 450MHz