Brand:

Dini Argeo, 3590EGT-IECEX3GD “TOUCH” : Touch Screen Indicator for Ex 2 & 22 Zones

Call for price

Call for price
Call for price
  • IECEx certification.
  • New enclosure with screwless front closure for easy cleaning of the indicator.
  • PG7 and PG9 cable glands with adapters for 4 to 7 mm and 7 to 10 mm cable routing. Equipped with anti-friction system that does not require additional external cable fixing, as required by the IECEx scheme and ATEX directives.
  • Available in specific version for direct connection to load cells installed in zone 1/21 and 0/20.
GET QUOTATION

Brand:

Dini Argeo, 3590EGT-IECEX3GD “TOUCH” : Touch Screen Indicator for Ex 2 & 22 Zones

Call for price

Call for price
Call for price
  • IECEx certification.
  • New enclosure with screwless front closure for easy cleaning of the indicator.
  • PG7 and PG9 cable glands with adapters for 4 to 7 mm and 7 to 10 mm cable routing. Equipped with anti-friction system that does not require additional external cable fixing, as required by the IECEx scheme and ATEX directives.
  • Available in specific version for direct connection to load cells installed in zone 1/21 and 0/20.
GET QUOTATION

ModelDescriptionPrice
3590EGT-IECEX3GDZBEx colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).Call for price
3590EGT-IECEX3GDEx colour Touch Screen indicator for zone 2/22 with AF01 software. IP68 stainless steel enclosure. ATEX/IECEX II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).Call for price

Weight indicator with a big touch screen display, for ATEX 2 & 22 hazardous zones.
ATEX/IECEX marking:
II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gases
II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
ATEX/IECEX marking with intrinsically safe connection for load cells:
II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gases.
II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
Suitable for advanced industrial applications, it’s fitted with 3 serial ports, Ethernet communication port, configurable printouts and integrated alibi memory.
CE-M approvable (OIML R-76 / EN 45501).

 

Technical Features:

  • 5,7′ colour touch screen display.
  • Multilanguage software.
  • 15-key alphanumerical waterproof keyboard.
  • 3-way control light.
  • Selectable QWERTY, AZERTY or QWERTZ keyboard integrated in the touch screen.
  • Stainless steel waterproof enclosure, with new IP68 protection system.
  • Dimensions: 280x143x185mm.
  • Suitable for use on the table.
  • Real time clock and permanent data storage.
  • Alibi memory as standard, integrated on the motherboard.
  • Slot for built-in micro SD to record the configuration, logos, and customized screens (upon request).
  • Functions available with DINITOOLS utility
    – Configuration, data entry and print formatting.
    – Recording and filing of all the information on PC.
    – Complete retrieval of the configuration.
    – Instrument calibration with numeric values.
    – Customization of the screens.
  • 24-bit A/D converter, 4 channels, up to 3200 conv./sec. with automatic frequency selection and up to 8 signal linearisation points.
  • 4 independent analogue channels for weight reading (up to 2 in E-AF03 version).
  • Connection with up to 16 analogue load cells of 350 Ohm (45 load cells of 1000 Ohm).
  • Up to 10.000e OIML or multi-range 3 x 3000e @ 0,3 µV/d CE-M legal for trade.
  • Up to 1.000.000 displayable divisions for internal factory use, with internal resolution up to 3.000.000 points.
  • Connectable to printers and labellers with free programming of the printout formats.
  • Power supply from 110-240Vac line or 12-24 Vdc Max. 25.2W

 

I/O SECTION 

  • 2 RS232 serial ports on terminals, for connection to printer, PC, radio module and optional interfaces.
  • 1 RS485/RS232 serial port on terminals, for connection to weight repeater,remote scale, badge readers or digital load cells.
  • 4 serial optoisolated outputs, up to 16 with optional board.
  • 2 serial optoisolated inputs, up to 8 with optional board.
  • Profibus or Modbus/TCP interface to install in safety zone.
  • External Profinet, Ethernet/IP, EtherCAT, CANopen and DeviceNet interface to install in safety zone. (optional, only with standard AF01 weighing program).
  • Modbus RTU Interface.
  • Optional Bluetooth connection, for fast wireless programming of archives, via PC, tablet or smartphone.
  • Analog output DAC16O requires IOEXPB expansion board.

 

STANDARD APPLICATIONS

  • AF01: Totalization and formula weighing
    OPZIONALI:
  • AF02: Piece/quantity counting
  • AF03: Weighbridges – Vehicle In/Out
  • AF04: Statistical check of prepackaged goods
  • AF05: Price computing and industrial labelling
  • AF08: Static wheel and axle weighing with 2 or more pads
  • AF09: Software for dynamic or static axle weighing with 1 or 2 pads
  • BATCH1: Single product dosage systems in loading and unloading
  • BATCH: Software for multicomponent dosage systems in loading and unloading (requires IOEXPB expansion board)

 

 

Additional information

Model

,

Description

Ex colour Touch Screen indicator for zone 2/22 with AF01 software. IP68 stainless steel enclosure. ATEX/IECEX II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT)., Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas and II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).